Skip to main content
LOW997Industrial Systems
VX-450 explosion-proof vibration transmitter with M12 connector and hexagonal mounting stud

Industrial Sensors & Instrumentation

VX-450 Explosion-Proof Vibration Transmitter

Model VX-450

ATEX Zone 1 condition-monitoring transmitter with on-board FFT, Modbus RTU and 4–20 mA in a 316L housing.

  • CE — EMC Directive 2014/30/EU
  • ATEX 2014/34/EU — Zone 1, Ex ia IIC T4 Ga
  • IECEx — Ex ia IIC T4 Ga
  • ISO 9001:2015 — Quality management system
  • RoHS 3 — EU 2015/863
Model number
VX-450
Voltage class
DC ≤ 60 V (SELV)
Minimum order
10 units
Standard lead time
21 days

Technical specification

Figures are for the standard configuration. Variants are quoted with a revised specification sheet.

Technical specifications for VX-450 Explosion-Proof Vibration Transmitter
Sensor elementIEPE piezoelectric accelerometer
Measurement range± 50 g peak
Frequency response0.5 Hz – 10 000 Hz (± 3 dB)
Sensitivity100 mV/g ± 5 %
Sampling rate25.6 kS/s
On-board FFT800 lines, Hanning window
Analog output4–20 mA, velocity RMS (ISO 10816)
Digital outputRS-485, Modbus RTU, 115.2 kbit/s
Supply voltage24 V DC, 12–32 V DC range
Operating temperature−40 °C to +125 °C
Enclosure316L stainless steel, IP68 / IP69K
Hazardous area ratingATEX Zone 1 II 2G Ex ia IIC T4 Ga / IECEx
Shock limit5 000 g peak, 1 ms half-sine
Mass0.42 kg

Dimensions and interfaces

Footprint and connection geometry, so the mechanical fit can be checked before the hydraulic or electrical design is finalised.

Dimensions and interfaces for VX-450 Explosion-Proof Vibration Transmitter
Body diameter31 mm
Body length78 mm (excluding connector)
Mounting threadM8 × 1.25 male stud
ConnectorM12 A-coded, 5-pin
Mass0.42 kg

Typical applications

  • Pump, fan and compressor condition monitoring
  • Wind turbine drivetrain and gearbox monitoring
  • Pulp, paper and mining crusher bearings
  • Refinery and petrochemical rotating equipment
  • Cooling tower and cooling-water pump sets

Application segments

Indexed on the same axes as the rest of the catalogue, so this line appears in the selection matrix for each segment below.

Product overview

Condition monitoring without the infrastructure

A conventional monitoring point needs an accelerometer, a shielded cable run, an intrinsically safe barrier, a junction box and a licensed electrician to open it. The VX-450 removes all four: it is the sensor, the barrier, the analyser and the data interface in one threaded body.

Because the FFT runs on the device, the RS-485 loop carries a decision instead of a waveform. A typical retrofit drops bus traffic by two orders of magnitude versus raw streaming, which means a single Modbus segment can carry 64 transmitters on ordinary twisted pair.

What you get on the wire

  • 4–20 mA velocity RMS — scaled to ISO 10816 zones, wired straight into an existing PLC analogue card for trending and alarms.
  • Modbus RTU registers — raw acceleration, velocity and envelope values, plus the 800-line spectrum on demand.
  • Bearing envelope band — a factory-set high-frequency band for early-stage rolling element defect detection, independent of the overall RMS trend.

Built for where vibration actually happens

The 316L housing carries IP68 / IP69K, so washdown and driven-rain installations are fine. The element survives a 5 000 g half-sine shock, which matters on crushers and screens where a sensor that survives normal operation is not the same as a sensor that survives a tramp-metal event.

The M12 A-coded connector means cable replacement takes seconds and does not require re-certifying the hazardous-area installation.

Deployment

Standard lead time is 21 days, minimum order quantity 10 units. Each transmitter ships with a calibration certificate traceable to a DAkkS-accredited laboratory, the ATEX / IECEx certificate set, and a Modbus register map. Engineering support during commissioning is available to OEM and integrator partners at no additional cost.

  • BR-48100 rack-mounted LiFePO4 battery module with front terminal studs and RJ45 communication ports

    Energy Storage & Power Conversion

    BR-48100 Rack-Mounted LiFePO4 Battery Module

    Model BR-48100

    51.2 V / 100 Ah lithium iron phosphate module with an integrated BMS and CAN telemetry, sized for 19-inch cabinets in telecom and commercial sites.

    Cell chemistry
    LiFePO4 (LFP), prismatic
    Nominal voltage
    51.2 V DC
    • UL 1973
    • IEC 62619
    • UN 38.3
    View specifications
  • HP-100 hybrid power conversion system in an IP66 outdoor enclosure with separate AC and DC cable entries

    Energy Storage & Power Conversion

    HP-100 Hybrid Power Conversion System

    Model HP-100

    100 kW bidirectional converter with dual MPPT inputs and grid-forming backup transfer in 10 ms, rated IP66 for outdoor installation.

    Rated AC power
    100 kW, four-quadrant bidirectional
    AC connection
    400 V AC three-phase + N + PE, 50 / 60 Hz
    • UL 1741 SB
    • IEC 62477-1
    • IEC 62109-1 / -2
    View specifications
  • LX-900 axial piston pump with ISO 3019/2 mounting flange and SAE J518 port block

    Hydraulic Pumps & Power Units

    LX-900 Heavy-Duty Axial Piston Pump

    Model LX-900

    420 bar rated variable-displacement pump for continuous duty on presses, steel lines and offshore deck machinery.

    Type
    Variable displacement, swashplate axial piston
    Displacement
    90 cm³/rev
    • CE
    • ISO 9001:2015
    • RoHS 3
    View specifications